SmartLink Connect Installation Instructions
MODEL
SmartLink Connect for Hunter ACC2 2-Wire Controller
2 Open the Hunter ACC2 panel and switch off power to the controller using the rocker switch located at the bottom left. Disconnect the modular cable from the housing. Then, remove the panel by pressing the control panel release on the upper right side of the panel assembly.
NOTE: Do not remove the existing ground wire.
4 Insert one end of the second included WHITE pre-cut wire into terminal (4) AC2 | 24VAC on the SmartLink Connect, and the other end to the 24VAC terminal on the power supply board.
Note: The SmartLink Connect comes with a jumper loop pre-installed in terminals (5) and (6), which should remain in place unless a wired or wireless rain sensor is being installed.
Note: Terminal (7) FIELD COM is not applicable in 2-wire system installations.
7 Reinstall the panel and power up the controller.
8 The LED on the SmartLink Connect will initially display red, indicating the device is OFF. Slide the switch to the ON position, and the LED will turn green. In order for the SmartLink Connect to communicate with the Aircard the LED must be green.
9 Refer to the Aircard instructions to add the controller to your portfolio.
Model: SL-CONNECT-HTR
Input: 24 V~, 60 Hz, 300 mA
ENV: -20C – 60C, INDOOR
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.