PROBLEM: Controller does not turn on zone when expected
CAUSES | SOLUTIONS |
Sensor jumper is removed and no sensor is connected (Sensor LED is red) | Install jumper wire between SEN terminals Select OFF mode if desired |
Sensor wires have been cut (Sensor LED is red) | Repair wires |
Zone comes on at unexpected time | Program daily start times not set properly or multiple start times set. Check Program Start Times |
Stacked program has commenced normal operation | Modify settings (such as program start times, zone run times) to prevent stacking if undesirable |
Time of day or date not set properly | Review/set time of day and date |
Watering days or omit days/dates not set properly | Review/set watering days or omit days/dates |
Run/Soak feature has extended watering window | Normal operation to allow water infiltration and prevent runoff |
Controller does not operate zone for expected run time | Pause for Run/Soak in progress. This is normal operation to allow water infiltration and prevent runoff |
Module not installed | Install module |
No initial AC power-up of controller | Connect AC power and close control panel |
Zone set to OFF | Set zone run time |
Dial set to SYSTEM OFF | Position Turn dial to RUN |
No zone run time set; no daily start time set | Program zone run time and daily start time |
Omit times/days are activated | Verify omit times/days |
Rain or freeze sensor has stopped watering (Sensor LED is red) | Replace sensor if faulty Select OFF mode if desired Reset start time to later in the day to avoid early morning freezing temperatures. |