SmartLink by Weathermatic   |    Catalogs    |    Support

Weathermatic
Weatherematic
CATALOGS   |   SUPPORT SmartLink by Weathermatic
Weathermatic

DI47R Installation Guide

Print

REPLACES: Rain Bird® 47D and 51D Series Impact Drives

STEP 1: Install New Nozzle

  1. Remove screws (2) on top of nozzle cap.
  2. Pull off nozzle cap.
  3. Snap in correct nozzle. (see Performance Chart)
  4. To remove nozzle, pull out using snap ring tool or screwdriver.

STEP 2: Adjustable Part Circle Option

  1. Rotate EASY ARC TABS to desired arc.
  2. Using a small screw driver or pointed object, move right and left tabs on each side of the Nozzle Marker. Example 180˚
  3. Replace EASY ARC cap.

NOTE: For part circle operation, make sure nozzle faces area to be irrigated.

STEP 3: Install Drive Assembly

  1. Reinstall cap with screws (2).
  2. Install new snap ring under cap.
  3. Place assembly in body.
  4. Push assembly until flush.
  5. Using tool push down in snap ring slots (2) until click in.