SLFSI-SXX Flow Sensor Technical Specifications
SLFSI-SXX Flow Sensor Technical Specifications
File | Action |
---|---|
Technical Specs – SLFSI-SXX Flow Sensor.pdf | Download |
Transducer Performance
- Quiescent current: 600 uA@8 VDC to 35 VDC max.
- Quiescent voltage: (VHigh) = Supply Voltage – (600uA X Supply Impedance)
- On State: (VLow) = Max. 1.2 VDC@50mA current limit, (10Ω +0.7VDC)
Flow Range
- 0.25 to 12 FPS
- 3-inch saddle: 6 to 300 GPM
- 4-inch saddle: 10 to 480 GPM
- 6-inch saddle: 45 to 1100 GPM
Electrical Cable
- 2 single conductor solid copper U.L. listed #18 AWG leads with direct burial insulation
- Lead length: 48 inches
- Wiring may be extended up to 2,000 feet with direct burial, twisted pair shielded cable
FEATURES
- Molded Mounting Tee for improved control of dimensions for more consistent measurement and improved performance at low flow.
- Threaded Retaining Nut instead of retaining pin makes it easier to service in a valve box, more moisture resistance for electronics resulting in longer life.
- Unique 4 bladed lightweight impeller measures lower flow rates. Detects flow as low as 20% of published minimum rate of other impeller sensors
- Smart electronics detection system contains a micro-processor for better signal filtering and conditioning. Detection circuit also contains superior over-voltage and overcurrent protection.
Professional Materials
- Impeller – HDPE (High Density Polyethylene
- Shaft – Tungsten Carbide
- O-ring — Buna-N
- Saddle, Sensor Housing, Retaining Nut — Type 1 PVC
Pressure Rating
- 150 PSI @ 90 degrees F
Temperature Range
- 32 degrees F to 140 degrees F (0 degrees to 60 degrees C)
Output Signal
- Frequency Range: 0.3 Hz to 200 Hz
- Output Pulse: 5 ms +/-25%