SmartLink
-
-
Controllers
-
-
-
-
- SmartWire SL9600TW 2-Wire Controller CSI Specifications
- SmartWire Solar SL4800TW CSI Specifications
- SmartLink SmartWire Solar SL4800TW Flow CSI Specifications
- SmartLink SmartWire Solar SL4800TW CSI Specifications
- SmartWire Solar SL4800TW w/ SLW CSI Specifications
- SmartWire Solar SL9600TW CSI Specifications
- SmartWire SL-WIRE Twisted Pair Wire CSI Specifications
- SmartWire SLDEC Valve Decoder CSI Specifications
- SmartWire SLGDT Lightning Arrestor CSI Specifications
-
-
- SmartLine Solar SLSOLAR48 CSI Specifications
- SmartLink Flow Solar SLSOLAR48 CSI Specifications
- SmartLink Solar SLSOLAR48 CSI Specifications
- SmartLink Solar SLSOLAR48 w/ SLW CSI Specifications
- SmartWire Solar SL4800TW CSI Specifications
- SmartLink SmartWire Solar SL4800TW Flow CSI Specifications
- SmartLink SmartWire Solar SL4800TW CSI Specifications
- SmartWire Solar SL4800TW w/ SLW CSI Specifications
- SmartWire Solar SL9600TW CSI Specifications
-
-
-
- Metal Wall Mount Enclosure SLWMM Written Specifications
- Powder-Coated Metal Enclosure with Pedestal SLPED-ENC-M Written Specifications
- Stainless Steel Enclosure with Pedestal SLPED-ENC-SS Written Specifications
- Stainless Steel Pedestal SLPED Written Specifications
- Stainless Steel Wall Mount Cabinet SLWMSS Written Specifications
-
-
-
Valves
-
-
Sprays
Black Max Valve Technical Specifications
Table of Contents
File | Action |
---|---|
Technical Specs – 11000 Series.pdf | Download |
FEATURES
- 10 year warranty and 100% water tested
- 225 psi (15,5 bar) rating
- S24B high-efficiency solenoid for positive opening at high pressures. Stainless steel actuator and brass threads
- Unique “reverse flow” porting design permits equal pressure distribution on both sides of the diaphragm, regardless of line pressure providing zero stress to prevent “stretching,” a common cause of valve failure
- Normally closed valve for water conservation
- Diaphragm’s self cleaning ports constantly flex, inhibiting sand and silt from blocking valve action
- Brass shock cone for smooth operation and reduction of water hammer
- Easy-to-use internal manual bleed lever; bleeds valve downstream; has stops for open and closed positions
- High-strength glass-filled body and cover with 1⁄4 in. stainless steel cover bolts and mating brass body inserts
- Brass non-rising flow control stem throttles valve from full open to closed position
- Excellent for micro-irrigation
- Contamination resistant (CR)
- Chloramine resistant diaphragm
ELECTRICAL
Wiring requires a single lead from the controller to each solenoid, plus a common neutral to all solenoids; type UF wire, U.L. listed, is recommended for all hookups
- 24VAC/60 Hz 24 VAC/50 Hz
- Inrush: 9.86 VA Inrush: 10.7 VA
- Holding: 5.69 VA Holding: 7.5 VA
Do not use nominal voltage ratings listed above for sizing of valve wires
INSTALLATION
- Teflon tape is recommended
- 1 in. FIP can be bushed to 3⁄4 in.
- 1 1⁄2 in. FIP can be bushed to 1 1⁄4 in.
*International threads (specify ISO)
Tags: