Project Description

Threaded retaining nut makes it easier to service in a valve box
- The molded mounting tee provides consistent measurements and overall improved performance
- Four bladed lightweight impeller is sensitive enough to measure lower flow rates
- Smart electronics capable of better signal filtering
- Affordable enough to install on nearly all new and old systems
SLFSI-TXX |
SLFSI-SXX |
SLFSI-BXX |
|
---|---|---|---|
Models | SLFSI-T10 1″ Tee Type Insert Flow Sensor – Used with the SmartLink Flow Aircard SLFSI-T15 SLFSI-T20 |
SLFSI-S30 3″ Saddle Type Insert Flow Sensor – Used with the SmartLink Flow Aircard SLFSI-S40 |
SLFSI-B15 1 1⁄2″ Brass Tee Type Insert Flow Sensor – Used with the SmartLink Flow Aircard |
Professional Materials | Impeller – HDPE (High Density Polyethylene) Shaft – Tungsten Carbide O-ring — Buna-N Saddle, Sensor Housing, Retaining Nut — Type 1 PVC |
Impeller – HDPE (High Density Polyethylene) Mounting Tee & Retaining Nut – Lead Free Bronze Alloy C89833 Federalloy I-836 Shaft – Tungsten Carbide O-ring — Buna-N Sensor Insert – Type 1 PVC |
|
Pressure Rating | 150 PSI @ 90º F | 250 PSI Maximum working pressure | |
Temperature Range | 32º F to 140º F (0º to 60º C) | ||
Output Signal | Frequency Range: 0.3 Hz to 200 Hz Output Pulse: 5 ms +/-25% |
||
Transducer Performance | Quiescent current: 600 uA@8 VDC to 35 VDC max. Quiescent voltage: (VHigh)= Supply Voltage – (600uA X Supply Impedance) On State: (VLow)= Max. 1.2 VDC@50mA current limit, (10Ω +0.7VDC) |
Quiescent current: 120 uA@8 VDC to 35 VDC max. Off State: (VHigh)= Supply Voltage – (120uA X Source Resistance) On State: (VLow)= Max. 0.85 Volts@50mA, (10Ω +0.7VDC) |
|
Flow Range | 0.25 to 12 FPS | 0.50 to 15 FPS | |
1″ tee: 0.86 to 52 GPM 1 1⁄2″ tee: 1.8 to 108 GPM 2″ tee: 2.8 to 170 GPM |
3″ saddle: 6 to 300 GPM 4″ saddle: 10 to 480 GPM |
3 to 90 GPM (11 to 340 LPM) | |
Electrical Cable | 2 single conductor solid copper U.L. listed #18 AWG leads with direct burial insulation Lead length: 48 inches Wiring may be extended up to 2,000 feet with direct burial, twisted pair shielded cable |
Select category or search...
Sales Sheets & Brochures
Manuals & Installation Instructions
![]() |
SLF-WIRERIDE Installation Instructions |
![]() |
SLFSI-TXX Flow Sensor Manual |
![]() |
SLFSI-SXX Flow Sensor Manual |
![]() |
SLFSI-BXX Flow Sensor Manual |
![]() |
SLF-ISOFLOW306 Installation Instructions |
![]() |
SLF-ISOFLOW300 Installation Instructions |
![]() |
SLF-COMBIFLOW Installation Instructions |